      產品中心您現在的位置:首頁 > 產品展示 > 液相配件 > 去除裝置 > Dionex CRD碳酸鹽去除裝置

      Dionex CRD碳酸鹽去除裝置

      更新時間:2019-11-18

      簡要描述:

      Dionex CRD碳酸鹽去除裝置
      從抑制洗脫液流通過擴散通過碳酸酯的選擇性透氣膜的壁除去二氧化碳。

      Dionex CRD碳酸鹽去除裝置

       

      Thermo Scientific的戴安™酸鹽去除裝置(CRD 180,200和300)從抑制洗脫液流通過擴散通過碳酸酯的選擇性透氣膜的壁除去二氧化碳。與碳酸洗脫液系統的戴安CRD 300降低了背景信號,以幾乎相同的水平作為氫氧化物洗脫液。抑制器后鉛垂,二氧化碳傳輸是由堿性溶液的逆流輔助。

      戴安CRD 180和200用于從氫氧化物洗脫液系統中除去碳酸優化
      盡量減少使用戴安CRD 180或200可以提高量化碳酸鹽
      戴安CRD 180的減小的膜長度為根據4微米樹脂柱優化
      戴安CRD 300的增加的膜長度為碳酸鹽淋洗液系統進行了優化
      減少與戴安CRD 300結果基線為碳酸鹽淋洗液系統更高的靈敏度
      與一戴安CRD 300碳酸背景消除增加了線性范圍

       

       

      Dionex CRD碳酸鹽去除裝置

      訂貨信息:

      CRD 180   (0.4 mm)                                  079960     
      CRD 200 (4 mm)     062983
      CRD 200 (2 mm)     062986
      CRD 200 (0.4 mm)     072054
      CRD 300 (4 mm)     064637
      CRD 300 (2 mm)     064638
      CRD 300 (4 mm) with Peristaltic Pump Kit     064905
      CRD 300 (2 mm) with Peristaltic Pump Kit     064906
      Santoprene Tubing for Peristaltic Pump     068518
      Ship Kit for Peristaltic Pump/CRD 300     064911
      CRD 300 (4 mm) with VP Vacuum Pump Kit     068475
      CRD 300 (2 mm) with VP Vacuum Pump Kit     068474

       

      Reduces Carbonate for Improved Sensitivity

      The Thermo Scientific Dionex Carbonate Removal Device (CRD 180, 200 and 300) remove carbon dioxide from the suppressed eluent stream by diffusion through the walls of a carbonate selective gas permeable membrane. With carbonate eluent systems the Dionex CRD 300 reduces the background signal to nearly the same levels as that of hydroxide eluents. Plumbed after the suppressor, the carbon dioxide transfer is aided by a countercurrent flow of basic solution.

      • The Dionex CRD 180 and 200 are optimized for the removal of carbonate from hydroxide eluent systems

      • Minimizing carbonate using the Dionex CRD 180 or 200 can improve quantification

      • The reduced membrane length of the Dionex CRD 180 is optimized for columns based on 4 μm resins

      • The increased membrane length of the Dionex CRD 300 is optimized for carbonate eluent systems

      • Reducing the baseline with a Dionex CRD 300 results in higher sensitivity for carbonate eluent systems

      • Elimination of the carbonic acid background with a Dionex CRD 300 increases the linearity range

      Dionex CRD 200 Carbonate Removal Device

      Exposure to carbon dioxide can cause samples to become contaminated with carbonate. High levels of carbonate originating from dissolved carbon dioxide can interfere with the accurate determination of analytes of interest, such as sulfate and nitrite. The Dionex CRD 200 is a device used to remove the carbonate peak contributed by the sample.

      The Dionex CRD 200 can be installed easily in any Thermo Scientific Dionex IC system equipped with an eluent generator, Thermo Scientific Dionex CR-ATC Continuously Regenerated Anion Trap Column, and Thermo Scientific Dionex AERS 500 Anion Electrolytically Regenerated Suppressor or Thermo Scientific Dionex ACES 300 Anion Capillary Electrolytic Suppressor, and requires no reagents or software control. The Dionex CRD 200 is a low-dispersion devices designed specifically for use with hydroxide- and borate-based chemistries using Thermo Scientific Dionex columns.

      The Dionex CRD 200 is available in three formats. The Dionex CRD 200 (4 mm) supports carbonate removal from standard bore systems, while the Dionex CRD 200 (2 mm) supports carbonate removal from microbore systems; the Dionex CRD 200 (0.4 mm) supports carbonate removal from capillary-scale systems at flow rates of 5 – 30 μL/min.

       

      A significant amount of carbonate is removed using the Dionex CRD 200 Carbonate Removal Device.

      Dionex CRD 300 Carbonate Removal Device

      Carbonate eluents are suppressed to relatively low-conductivity carbonate acid, but the residual conductivity of the carbonic acid has several undesirable effects. Carbonic acid can mask small peaks, decreasing the limit of detection (LOD) during trace analyses. In a background of carbonic acid, the linear range of most species is limited, and the residual background conductivity creates a large void dip which can hamper the integration of early eluting species. The CRD 300 is a device used to remove the carbonic acid from the suppressed eluent, providing hydroxide-like detection to systems using carbonate eluents.

      The Dionex CRD 300 can be installed easily in any Dionex IC system running carbonate as an eluent with a Dionex AERS 500 suppressor. The Dionex CRD 300 requires either a constant flow of basic solution from a peristaltic pump or evacuation by a vacuum pump. The Dionex CRD 300 is designed specifically for use with carbonate eluent based chemistries using Dionex columns.

      The Dionex CRD 300 is available in two formats. The Dionex CRD 300 (4 mm) supports carbonate removal from standard bore systems, while the Dionex CRD 300 (2 mm) supports carbonate removal from microbore systems.

       

      Background signal is reduced using the Dionex CRD 300 Carbonate Removal Device.

      Dionex CRD 180 Carbonate Removal Device

      The Dionex CRD 180 is a version of the Dionex CRD 200 that has reduced internal volume. This facilitates operation in conjunction with 4 μm resin packed capillary columns without unacceptable loss of peak efficiency. However the Dionex CRD 180 has less capacity for the removal of carbonate than the Dionex CRD 200, and is therefore not recommended for use with columns packed with resin larger than 4 μm.

      The Dionex CRD 180 can be installed easily in a Dionex Capillary IC system equipped with an eluent generator, Dionex CR-ATC Continuously Regenerated Anion Trap Column, and Dionex ACES 300 suppressor. The Dionex CRD 180 requires no reagents or software control. The Dionex CRD 180 is an ultra-low-dispersion device designed specifically for use with hydroxide-based chemistries using Dionex columns.

      The Dionex CRD 180 is only available in capillary (0.4 mm) format for use with 0.25 mm and 0.4 mm capillary columns. Microbore and standard-bore systems using 4 μm resin packed columns should use the Dionex CRD 200.

      Dionex Carbonate Removal Device CRD 180 Specifications
      Hardware Dimensions
      ( h × w × d)
      11.3 cm × 9.3 cm × 2.1cm
      (4.5 in. × 3.7 in. × 0.8 in.)
      Void Volume0.4 mm: ~1 μL

       

      Dionex Carbonate Removal Device CRD 200 Specifications
      Hardware Dimensions
      ( h × w × d) (4 mm and 2 mm)
      2.0 cm × 4.4 cm × 7cm
      (0.8 in. × 1.7 in. × 2.8 in.)
      Hardware Dimensions
      ( h × w × d) (0.4 mm)
      11.3 cm × 9.3 cm × 2.1cm
      (4.5 in. × 3.7 in. × 0.8 in.)
      Void Volume2 mm: ~40 μL
      4 mm: ~200 μL
      0.4 mm: ~2 μL

       

      Dionex Carbonate Removal Device CRD 300 Specifications
      Hardware Dimensions
      ( h × w × d)
      2.0 cm × 4.4 cm × 7cm
      (0.8 in. × 1.7 in. × 2.8 in.)
      Void Volume2 mm: 80 μL
      4 mm: 225 μL

       

       

        沒有相關產品信息...

      留言框

      • 產品:

      • 您的單位:

      • 您的姓名:

      • 聯系電話:

      • 常用郵箱:

      • 省份:

      • 詳細地址:

      • 補充說明:

      • 驗證碼:

        請輸入計算結果(填寫阿拉伯數字),如:三加四=7
      主站蜘蛛池模板: 亚洲人成在线影院| 久久久久国产亚洲AV麻豆| 成人免费777777被爆出| 一二三区免费视频| 国产啪精品视频网站免费尤物| 高清永久免费观看| 全免费一级午夜毛片| 免费精品国产自产拍观看| 国产免费av一区二区三区| 亚洲国产成+人+综合| 男人的天堂av亚洲一区2区| 免费看又黄又爽又猛的视频软件| 四虎影视久久久免费观看| 免费看黄的成人APP| 亚洲国模精品一区| 亚洲国色天香视频| 日本特黄特色AAA大片免费| 国内自产少妇自拍区免费| 77777亚洲午夜久久多人| 亚洲视频免费在线播放| 欧洲亚洲综合一区二区三区| 波多野结衣免费一区视频| 相泽亚洲一区中文字幕| 国产精品99爱免费视频| 久久精品网站免费观看| 亚洲精品国产高清嫩草影院| 黄色a三级免费看| 99久9在线|免费| 免费观看亚洲人成网站| 美女视频黄频a免费| 亚洲日韩在线观看| 亚洲AV噜噜一区二区三区| 国产精品视_精品国产免费| 亚洲精品成人久久| aaa毛片免费观看| 日韩成人免费aa在线看| 亚洲国产综合专区电影在线| 69视频在线观看免费| 国产AV无码专区亚洲AVJULIA| 亚洲精品第一国产综合亚AV| 91福利视频免费|